In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a2 + b2]1/2
 
Result of the search
Your selection : Thermometry, Temperature
 
Zambia, ZMA (Zambia Metrology Agency)
Complete CMCs in Thermometry for Zambia (.PDF file)
Temperature. Base metal thermocouple, 220 °C to 280 °C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in °C: 1.0
Comparison in dry block calibrator
Type N thermocouple. Calculated values of inhomogeneity included in the CMC calculation.
Approved on 06 November 2018
Internal NMI service identifier: ZMASIL
 
Temperature. Base metal thermocouple, 280 °C to 450 °C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in °C: 1.0
Comparison in dry block calibrator
Type N thermocouple. Calculated values of inhomogeneity included in the CMC calculation.
Approved on 06 November 2018
Internal NMI service identifier: ZMASIL
 
Temperature. Industrial platinum resistance thermometer, -40 °C to 0 °C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in °C: 0.05
Comparison in liquid bath
Nominal Hysterisis is included in the uncertainity calculation. The uncertainty claimed is maximum for the whole range.
Approved on 06 November 2018
Internal NMI service identifier: ZMASIL
 
Temperature. Industrial platinum resistance thermometer, 0 °C to 220 °C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in °C: 0.5
Comparison in liquid bath
Nominal Hysterisis is included in the uncertainity calculation. The uncertainty claimed is maximum for the whole range.
Approved on 06 November 2018
Internal NMI service identifier: ZMASIL
 
Temperature. Industrial platinum resistance thermometer, 220 °C to 280 °C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in °C: 0.81
Comparison in dry block calibrator
Nominal Hysterisis is included in the uncertainity calculation. The uncertainty claimed is maximum for the whole range.
Approved on 06 November 2018
Internal NMI service identifier: ZMASIL
 
Temperature. Industrial platinum resistance thermometer, 280 °C to 450 °C
Absolute expanded uncertainty (k = 2, level of confidence 95 %) in °C: 0.93
Comparison in dry block calibrator
Nominal Hysterisis is included in the uncertainity calculation. The uncertainty claimed is maximum for the whole range.
Approved on 06 November 2018
Internal NMI service identifier: ZMASIL


 