In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a2 + b2]1/2
 
Result of the search
Your selection : Ionizing Radiation, Dosimetry, Austria
 
Austria, BEV (Bundesamt für Eich- und Vermessungswesen)
Complete CMCs in Ionizing Radiation for Austria (.pdf file)
Absorbed dose rate to water. Dosemeter, 1E-03 Gy s-1 to 1E-02 Gy s-1
Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 3.0
Conversion coefficient (µ/r)w,a·B, calibration on PMMA phantom against a calibrated monitor chamber free in air
(µ/r)w,a: ratio of the average mass energy absorption coefficients of water and air
B: backscatter-correction factor (DIN 6809-4)
X-ray, 10 kV to 50 kV: BIPM-CCEMRI: 1972, 10 kV to 50 kV, max. 60 mA
Reference standard: Free air parallel plate ionisation chamber
Source of traceability: BEV
Approved on 24 January 2012
Internal NMI service identifier: EUR-RAD-BEV-1001
 
Absorbed dose rate to water. Dosemeter, 1E-03 Gy s-1 to 5E-02 Gy s-1
Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 0.9
Graphite calorimeter plus conversion procedure, calibration in water phantom, transfer chamber to calibrate a user beam
Co-60: 42 TBq (31.12.2008), 100 cm SDD, 10 cm x 10 cm FS
Reference standard: Graphite calorimeter
Source of traceability: BEV
Approved on 24 January 2012
Internal NMI service identifier: EUR-RAD-BEV-1002
 
Air kerma length product. Dosemeter, 1E-05 Gy cm to 5E+01 Gy cm
Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 1.5
Calibration against a calibrated monitor chamber free in air
X-ray, 50 kV to 420 kV: IEC 61267 RQR Series, 40 kV to 150 kV, max. 30 mA
Reference standard: Free air parallel plate ionisation chamber
Source of traceability: BEV
Approved on 24 January 2012
Internal NMI service identifier: EUR-RAD-BEV-1051
 
Air kerma length product. Dosemeter, 1E-06 Gy cm to 5E+00 Gy cm
Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 1.5
Calibration against a calibrated monitor chamber free in air
X-ray, 50 kV to 420 kV: IEC 61267 RQA Series, 40 kV to 150 kV, max. 30 mA
Reference standard: Free air parallel plate ionisation chamber
Source of traceability: BEV
Approved on 24 January 2012
Internal NMI service identifier: EUR-RAD-BEV-1052
 
Air kerma rate. Dosemeter, 1E-03 Gy h-1 to 1E-01 Gy h-1
Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 0.8
Calibration against a calibrated monitor chamber free in air
X-ray, 10 kV to 50 kV: ISO-4037 Narrow-spectrum Series, 10 kV to 40 kV, max. 60 mA
Reference standard: Free air parallel plate ionisation chamber
Source of traceability: BEV
Approved on 24 January 2012
Internal NMI service identifier: EUR-RAD-BEV-1016
 
Air kerma rate. Dosemeter, 1E-03 Gy h-1 to 1E-01 Gy h-1
Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 0.8
Calibration against a calibrated monitor chamber free in air
X-ray, 50 kV to 420 kV: ISO-4037 Narrow-spectrum Series, 60 kV to 300 kV, max. 30 mA
Reference standard: Free air parallel plate ionisation chamber
Source of traceability: BEV
Approved on 24 January 2012
Internal NMI service identifier: EUR-RAD-BEV-1017


 