Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
CMCs - Result of the search
Physics
Acoustics, Ultrasound, Vibration
Electricity and Magnetism
Length
Mass and related quantities
Photometry and Radiometry
Ionizing Radiation
Thermometry
Time and Frequency
Chemistry
Chemistry
Related links
KCDB Statistics
KCDB FAQs
KCDB Reports
CIPM MRA
JCRB
Find my NMI
Metrologia
Contact us
BIPM.KCDB@bipm.org
Calibration and Measurement Capabilities
Acoustics, Ultrasound, Vibration
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a2 + b2]1/2
 
Result of the search
Your selection : Acoustics, Ultrasound, Vibration
 
South Africa, NMISA (National Metrology Institute of South Africa)
Complete CMCs in Acoustics, Ultrasound, Vibration for South Africa (.PDF file)
Acceleration (modulus). Vibration measuring instrument, 0.01 m/s2 to 100 m/s2
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 1.5
ISO 16063-21
Frequency range: 3 Hz to 10 Hz
Approved on 19 December 2005
Calibration of velocity as well as displacement transducers is available
Internal NMI service identifier: NMISA/AV-21.1.1.1-1
 
Acceleration (modulus). Vibration measuring instrument, 0.01 m/s2 to 100 m/s2
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 1.0
ISO 16063-21
Frequency range: 10 Hz to 1 kHz
Approved on 19 December 2005
Calibration of velocity as well as displacement transducers is available
Internal NMI service identifier: NMISA/AV-21.1.1.1-1
 
Acceleration (modulus). Vibration measuring instrument, 0.01 m/s2 to 500 m/s2
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 1.3
ISO 16063-21
Frequency range: 1.25 kHz to 4.5 kHz
Approved on 05 January 2011
Calibration of velocity as well as displacement transducers is available
Internal NMI service identifier: NMISA/AV-21.1.1.1-1
 
Acceleration (modulus). Vibration measuring instrument, 0.01 m/s2 to 500 m/s2
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 2.0
ISO 16063-21
Frequency range: 5 kHz to 10 kHz
Approved on 19 December 2005
Calibration of velocity as well as displacement transducers is available
Internal NMI service identifier: NMISA/AV-21.1.1.1-1
 
Charge sensitivity (modulus). Accelerometer. Measurand unit,  pC/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.3
ISO 16063-11
Frequency: 0.4 Hz to 50 Hz
Approved on 11 May 2012
Internal NMI service identifier: NMISA/AV-21.3.1.1-1
 
Charge sensitivity (modulus). Accelerometer. Measurand unit,  pC/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.5
ISO 16063-11
Frequency: > 50 Hz to 1 kHz
Approved on 11 May 2012
Internal NMI service identifier: NMISA/AV-21.3.1.1-1


 
 1  2    3    [Next  >>]