Your selection : Electricity and Magnetism
|
| | | Singapore, NMC, A*STAR (National Metrology Centre, Agency for Science, Technology and Research) |
| | Complete CMCs in Electricity and Magnetism for Singapore (.PDF file) |  | | AC current up to 100 A: meter. Multimeter, ammeter, multifunction transfer standard, 0.0001 A to 10 A | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 35 to 440 | | AC-DC difference | | Frequency: 10 Hz to 10 kHz | | Approved on 19 March 2012 | | Internal NMI service identifier: NMC, A*STAR/LF112 | |
Uncertainty table
|
| | | AC current up to 100 A: source. Multifunction calibrator, transconductance amplifier, 0.0002 A to 10 A | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 35 to 430 | | AC-DC difference | | Frequency: 10 Hz to 10 kHz | | Measurement uncertainty is load dependent Approved on 19 March 2012 | | Internal NMI service identifier: NMC, A*STAR/LF111 | |
Uncertainty table
|
| | | AC high voltage: meters. AC high voltage meter, dedicated set-up for high voltage measurements (resistive and capacitive dividers), 1 kV to 10 kV | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in V: 16 | | Comparison with reference ratio transformer | | Frequency: 50 Hz | | Approved on 25 August 2008 | | Internal NMI service identifier: NMC, A*STAR/LF122 |
| | | AC high voltage: meters. AC high voltage meter, dedicated set-up for high voltage measurements (resistive and capacitive dividers), 10 kV to 30 kV | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in V: 66 | | Comparison with reference ratio transformer | | Frequency: 50 Hz | | Approved on 25 August 2008 | | Internal NMI service identifier: NMC, A*STAR/LF123 |
| | | AC high voltage: meters. AC high voltage meter, dedicated set-up for high voltage measurements (resistive and capacitive dividers), 30 kV to 100 kV | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in V: 160 | | Comparison with reference ratio transformer | | Frequency: 50 Hz | | Approved on 25 August 2008 | | Internal NMI service identifier: NMC, A*STAR/LF124 |
| | | AC high voltage: sources. High voltage AC source, 1 kV to 10 kV | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in V: 16 | | Comparison with reference ratio transformer | | Frequency: 50 Hz | | Approved on 25 August 2008 | | Internal NMI service identifier: NMC, A*STAR/LF119 |
|