| | | New Zealand, MSL (Measurement Standards Laboratory) |
| | Complete CMCs in Electricity and Magnetism for New Zealand (.PDF file) |  | | AC current ratio: imaginary component (or argument). Current transformer bridge, 0 rad to 0.002 rad | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in rad: 1.2E-06 to 2.0E-06 | | Inject known error current | | Frequency: 45 Hz to 65 Hz | | Approved on 22 November 2006 | | Internal NMI service identifier: MSL/84 |
| | | AC current ratio: imaginary component (or argument). Current transformer bridge, 0.002 rad to 0.02 rad | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in rad: 1.2E-05 to 1.9E-05 | | Inject known error current | | Frequency: 45 Hz to 65 Hz | | Approved on 22 November 2006 | | Internal NMI service identifier: MSL/85 |
| | | AC current ratio: imaginary component (or argument). Current transformer bridge, 0.02 rad to 0.2 rad | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in rad: 1.2E-04 to 1.8E-04 | | Inject known error current | | Frequency: 45 Hz to 65 Hz | | Approved on 22 November 2006 | | Internal NMI service identifier: MSL/86 |
| | | AC current ratio: real component (or modulus). Current transformer bridge, 0 to 0.002 | | Absolute expanded uncertainty (k = 2, level of confidence 95%): 1.2E-06 to 2.0E-06 | | Inject known error current | | Frequency: 45 Hz to 65 Hz | | Approved on 22 November 2006 | | Internal NMI service identifier: MSL/81 |
| | | AC current ratio: real component (or modulus). Current transformer bridge, 0.002 to 0.02 | | Absolute expanded uncertainty (k = 2, level of confidence 95%): 1.2E-05 to 2.0E-05 | | Inject known error current | | Frequency: 45 Hz to 65 Hz | | Approved on 22 November 2006 | | Internal NMI service identifier: MSL/82 |
| | | AC current ratio: real component (or modulus). Current transformer bridge, 0.02 to 0.2 | | Absolute expanded uncertainty (k = 2, level of confidence 95%): 1.2E-04 to 2.0E-04 | | Inject known error current | | Frequency: 45 Hz to 65 Hz | | Approved on 22 November 2006 | | Internal NMI service identifier: MSL/83 |
|