Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
CMCs - Result of the search
Physics
Acoustics, Ultrasound, Vibration
Electricity and Magnetism
Length
Mass and related quantities
Photometry and Radiometry
Ionizing Radiation
Thermometry
Time and Frequency
Chemistry
Chemistry
Traceability to the SI through the BIPM
BIPM calibration and measurement services
Related links
KCDB Statistics
KCDB FAQs
KCDB Reports
CIPM MRA
JCRB
Find my NMI
Metrologia
Contact us
BIPM.KCDB@bipm.org
Calibration and Measurement Capabilities
Electricity and Magnetism
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a2 + b2]1/2
 
Result of the search
Your selection : Electricity and Magnetism
 
New Zealand, MSL (Measurement Standards Laboratory)
Complete CMCs in Electricity and Magnetism for New Zealand (.PDF file)
AC current ratio: imaginary component (or argument). Current transformer bridge, 0 rad to 0.002 rad
Absolute expanded uncertainty (k = 2, level of confidence 95%) in rad: 1.2E-06 to 2.0E-06
Inject known error current
Frequency: 45 Hz to 65 Hz
Approved on 22 November 2006
Internal NMI service identifier: MSL/84
 
AC current ratio: imaginary component (or argument). Current transformer bridge, 0.002 rad to 0.02 rad
Absolute expanded uncertainty (k = 2, level of confidence 95%) in rad: 1.2E-05 to 1.9E-05
Inject known error current
Frequency: 45 Hz to 65 Hz
Approved on 22 November 2006
Internal NMI service identifier: MSL/85
 
AC current ratio: imaginary component (or argument). Current transformer bridge, 0.02 rad to 0.2 rad
Absolute expanded uncertainty (k = 2, level of confidence 95%) in rad: 1.2E-04 to 1.8E-04
Inject known error current
Frequency: 45 Hz to 65 Hz
Approved on 22 November 2006
Internal NMI service identifier: MSL/86
 
AC current ratio: real component (or modulus). Current transformer bridge, 0  to 0.002 
Absolute expanded uncertainty (k = 2, level of confidence 95%): 1.2E-06 to 2.0E-06
Inject known error current
Frequency: 45 Hz to 65 Hz
Approved on 22 November 2006
Internal NMI service identifier: MSL/81
 
AC current ratio: real component (or modulus). Current transformer bridge, 0.002  to 0.02 
Absolute expanded uncertainty (k = 2, level of confidence 95%): 1.2E-05 to 2.0E-05
Inject known error current
Frequency: 45 Hz to 65 Hz
Approved on 22 November 2006
Internal NMI service identifier: MSL/82
 
AC current ratio: real component (or modulus). Current transformer bridge, 0.02  to 0.2 
Absolute expanded uncertainty (k = 2, level of confidence 95%): 1.2E-04 to 2.0E-04
Inject known error current
Frequency: 45 Hz to 65 Hz
Approved on 22 November 2006
Internal NMI service identifier: MSL/83


 
 1  2    3    [Next  >>]