Electricity and Magnetism
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a2 + b2]1/2
 
Result of the search
Your selection : Electricity and Magnetism
 
Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Electricity and Magnetism for Korea, Republic of (.PDF file)
Magnetic fields below 50 kHz: turn area (ratio of magnetic flux and magnetic flux density). Sensing coils, area turns, 0.005 m2 to 0.3 m2
Relative expanded uncertainty (k = 2, level of confidence 95%) in cm2/m2: 50
Fluxmeter, NMR
Coil size: smaller than a square of side length 10 cm
Approved on 18 October 2004
Internal NMI service identifier: KRISS/89
 
AC current up to 100 A: meters. Multimeters: AC current, 0.001 A to 10 A
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 165 to 6500
Direct measurement
Frequency: 40 Hz to 10 kHz
Approved on 18 October 2004
Internal NMI service identifier: KRISS/73
Uncertainty table
 
AC current up to 100 A: sources. Multifunction calibrator, transconductance amplifier, 0.001 A to 10 A
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 70 to 220
Direct measurement
Frequency: 40 Hz to 10 kHz
Approved on 18 October 2004
Internal NMI service identifier: KRISS/72
Uncertainty table
 
AC high voltage: phase displacement. Voltage transformer, 0 min to 7 min
Absolute expanded uncertainty (k = 2, level of confidence 95%) in min: 0.14 to 0.29
Comparison with standard transformer
Voltage: 30 V to 33 kV
Frequency: 60 Hz
Approved on 25 August 2008
Internal NMI service identifier: KRISS/147
Uncertainty table
 
AC high voltage: phase displacement. Voltage transformer, 0 min to 7 min
Absolute expanded uncertainty (k = 2, level of confidence 95%) in min: 0.15 to 0.16
Comparison with standard transformer
Voltage: 55 kV to 200 kV
Frequency: 60 Hz
Approved on 25 August 2008
Internal NMI service identifier: KRISS/148
Uncertainty table
 
AC high voltage: ratio error. Voltage transformer, 0  to 0.002 
Absolute expanded uncertainty (k = 2, level of confidence 95%): 35E-06 to 60E-06
Comparison with standard transformer
Voltage: 30 V to 33 kV
Frequency: 60 Hz
Approved on 25 August 2008
Internal NMI service identifier: KRISS/145
Uncertainty table


 
 1  2    3    [Next  >>]