Your selection : Electricity and Magnetism
|
| | | Japan, NMIJ (National Metrology Institute of Japan) |
| | Complete CMCs in Electricity and Magnetism for Japan (.PDF file) |  | AC resistance: imaginary component. Fixed resistor, 1 k | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in µrad: 7.6 | | AC resistance bridge | | Frequency: 1 kHz | | Approval date: 19 March 2012 | | Traceable calibration service is available from accredited laboratories by JCSS. Refer to http://www.nite.go.jp | | Internal NMI service identifier: NMIJ/122 |
| | AC resistance: imaginary component. Fixed resistor, 10 k | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in µrad: 7.6 | | AC resistance bridge | | Frequency: 1 kHz | | Approval date: 19 March 2012 | | Traceable calibration service is available from accredited laboratories by JCSS. Refer to http://www.nite.go.jp | | Internal NMI service identifier: NMIJ/123 |
| | AC resistance: imaginary component. Fixed resistor, 100 k | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in µrad: 7.6 | | AC resistance bridge | | Frequency: 1 kHz | | Approval date: 19 March 2012 | | Traceable calibration service is available from accredited laboratories by JCSS. Refer to http://www.nite.go.jp | | Internal NMI service identifier: NMIJ/124 |
| | AC resistance: real component. Fixed resistor, 1 k | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 0.1 | | AC resistance bridge | | Frequency: 1 kHz | | Approval date: 24 August 2008 | | Traceable calibration service is available from accredited laboratories by JCSS. Refer to http://www.nite.go.jp | | Internal NMI service identifier: NMIJ/24 |
| | AC resistance: real component. Fixed resistor, 10 k | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 0.060 | | AC resistance bridge | | Frequency: 1 kHz | | Approval date: 24 August 2008 | | Traceable calibration service is available from accredited laboratories by JCSS. Refer to http://www.nite.go.jp | | Internal NMI service identifier: NMIJ/25 |
| | AC resistance: real component. Fixed resistor, 100 k | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 0.064 | | AC resistance bridge | | Frequency: 1 kHz | | Approval date: 24 August 2008 | | Traceable calibration service is available from accredited laboratories by JCSS. Refer to http://www.nite.go.jp | | Internal NMI service identifier: NMIJ/26 |
|