Your selection : Electricity and Magnetism
|
| | | Hong Kong, China, SCL (Standards and Calibration Laboratory) |
| | Complete CMCs in Electricity and Magnetism for Hong Kong, China (.PDF file) |  | | AC current up to 100 A: meters. AC ammeters, 0.0001 A to 1 A | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 120 to 400 | | By series comparison with a calibrated AC shunt | | Frequency: 40 Hz to 10 kHz | | Approved on 25 August 2008 | | Internal NMI service identifier: SCL/6.2.2-001 | |
Uncertainty table
|
| | | AC current up to 100 A: sources. Multifunction calibrator, transconductance amplifier, 0.005 A to 20 A | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 30 to 500 | | AC-DC transfer | | Frequency: 40 Hz to 10 kHz | | Approved on 25 August 2008 | | Internal NMI service identifier: SCL/6.2.1-001 | |
Uncertainty table
|
| | | AC current up to 100 A: sources. Multifunction calibrator, transconductance amplifier, 0.0025 A to 20 A | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 60 to 500 | | AC-DC transfer | | Frequency: 20 Hz to 10 kHz | | Approved on 25 August 2008 | | Internal NMI service identifier: SCL/6.2.1-002 | |
Uncertainty table
|
| | | AC current up to 100 A: sources. Multifunction calibrator, transconductance amplifier, 1 A to 100 A | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 80 | | Step down using current transformer | | Frequency: 45 Hz to 60 Hz | | Approved on 25 August 2008 | | Internal NMI service identifier: SCL/6.2.1-003 | |
Uncertainty table
|
| | | AC high voltage: meters. AC high voltage meter, dedicated set-up for high voltage measurement, 1 kV to 11 kV | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in V: 0.26 to 2.9 | | Comparison with reference system | | Frequency: 50 Hz | | Approved on 25 August 2008 | | Internal NMI service identifier: SCL/8.3.2-001 |
| | | AC high voltage: sources. High voltage AC source, 1 kV to 11 kV | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in V: 0.26 to 2.9 | | Direct measurement with reference system | | Frequency: 50 Hz | | Approved on 25 August 2008 | | Internal NMI service identifier: SCL/8.3.1-001 |
|