Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
CMCs - Result of the search
Physics
Acoustics, Ultrasound, Vibration
Electricity and Magnetism
Length
Mass and related quantities
Photometry and Radiometry
Ionizing Radiation
Thermometry
Time and Frequency
Chemistry
Chemistry
Traceability to the SI through the BIPM
BIPM calibration and measurement services
Related links
KCDB Statistics
KCDB FAQs
KCDB Reports
CIPM MRA
JCRB
Find my NMI
Metrologia
Contact us
BIPM.KCDB@bipm.org
Calibration and Measurement Capabilities
Electricity and Magnetism
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a2 + b2]1/2
 
Result of the search
Your selection : Electricity and Magnetism
 
Hong Kong, China, SCL (Standards and Calibration Laboratory)
Complete CMCs in Electricity and Magnetism for Hong Kong, China (.PDF file)
AC current up to 100 A: meters. AC ammeters, 0.0001 A to 1 A
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 120 to 400
By series comparison with a calibrated AC shunt
Frequency: 40 Hz to 10 kHz
Approved on 25 August 2008
Internal NMI service identifier: SCL/6.2.2-001
Uncertainty table
 
AC current up to 100 A: sources. Multifunction calibrator, transconductance amplifier, 0.005 A to 20 A
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 30 to 500
AC-DC transfer
Frequency: 40 Hz to 10 kHz
Approved on 25 August 2008
Internal NMI service identifier: SCL/6.2.1-001
Uncertainty table
 
AC current up to 100 A: sources. Multifunction calibrator, transconductance amplifier, 0.0025 A to 20 A
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 60 to 500
AC-DC transfer
Frequency: 20 Hz to 10 kHz
Approved on 25 August 2008
Internal NMI service identifier: SCL/6.2.1-002
Uncertainty table
 
AC current up to 100 A: sources. Multifunction calibrator, transconductance amplifier, 1 A to 100 A
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 80
Step down using current transformer
Frequency: 45 Hz to 60 Hz
Approved on 25 August 2008
Internal NMI service identifier: SCL/6.2.1-003
Uncertainty table
 
AC high voltage: meters. AC high voltage meter, dedicated set-up for high voltage measurement, 1 kV to 11 kV
Absolute expanded uncertainty (k = 2, level of confidence 95%) in V: 0.26 to 2.9
Comparison with reference system
Frequency: 50 Hz
Approved on 25 August 2008
Internal NMI service identifier: SCL/8.3.2-001
 
AC high voltage: sources. High voltage AC source, 1 kV to 11 kV
Absolute expanded uncertainty (k = 2, level of confidence 95%) in V: 0.26 to 2.9
Direct measurement with reference system
Frequency: 50 Hz
Approved on 25 August 2008
Internal NMI service identifier: SCL/8.3.1-001


 
 1  2    3    [Next  >>]