Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
CMCs - Result of the search
Physics
Acoustics, Ultrasound, Vibration
Electricity and Magnetism
Length
Mass and related quantities
Photometry and Radiometry
Ionizing Radiation
Thermometry
Time and Frequency
Chemistry
Chemistry
Traceability to the SI through the BIPM
BIPM calibration and measurement services
Related links
KCDB Statistics
KCDB FAQs
KCDB Reports
CIPM MRA
JCRB
Find my NMI
Metrologia
Contact us
BIPM.KCDB@bipm.org
Calibration and Measurement Capabilities
Electricity and Magnetism
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a2 + b2]1/2
 
Result of the search
Your selection : Electricity and Magnetism
 
Australia, NMIA (National Measurement Institute, Australia)
Complete CMCs in Electricity and Magnetism for Australia (.PDF file)
AC high voltage: meters. ACrms and ACpeak/(sqrt 2) voltmeters, 1 kV to 550 kV
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.1
Intercomparison
Frequency: 50 Hz
Approved on 25 August 2008
Internal NMI service identifier: NMIA/90
 
AC high voltage: phase displacement. VT, 0 crad to 0.11 crad
Absolute expanded uncertainty (k = 2, level of confidence 95%) in crad: 0.006
Current comparator
Ratio: 1 to 100000
Voltage: 550 kV maximum
Frequency: 50 Hz
Approved on 25 August 2008
Internal NMI service identifier: NMIA/85b
 
AC high voltage: ratio error. VT, 0 % to 90 %
Relative expanded uncertainty (k = 2, level of confidence 95%): 60E-06
Current comparator
Ratio: 1 to 10000
Voltage: 550 kV maximum
Frequency: 50 Hz
Approved on 25 August 2008
Internal NMI service identifier: NMIA/85a
 
AC high voltage: ratio error. VT, 1 %
Relative expanded uncertainty (k = 2, level of confidence 95%): 4E-06 to 15E-06
Clothier-Medina
Ratio: 1 to 1000
Voltage: 100 kV maximum
Frequency: 50 Hz
Approved on 25 August 2008
Internal NMI service identifier: NMIA/86
 
AC high voltage: ratio phase displacement. VT, -5 crad to 5 crad
Absolute expanded uncertainty (k = 2, level of confidence 95%) in crad: 0.0004 to 0.00151E-04
Clothier-Medina
Ratio: 1 to 1000
Voltage: 100 kV maximum
Frequency: 50 Hz
Approved on 25 August 2008
Internal NMI service identifier: NMIA/86a
 
AC power and energy: single phase. Power meter, energy meter, power converter, 0 W to 4800 W
Relative expanded uncertainty (k = 2, level of confidence 95%) in µW/VA: 10
Double bridge thermal power comparator
Frequency: 47 Hz to 60 Hz
Power factor: 1 to 0 L/C
Voltage: 60 V to 480 V
Current: 0.1 A to 10 A
Approved on 19 March 2012
Internal NMI service identifier: NMIA/57


 
 1  2    3    [Next  >>]