Physics |
|
|
|
|
Traceability to the SI through the BIPM |
|
|
|
|
Related links |
|
|
|
|
Contact us |
|
|
|
|
|
 |
Calibration and Measurement Capabilities Ionizing Radiation |
 |
| In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a2 + b2]1/2 |
| |
Result of the search |
 |
 |
Your selection : Ionizing Radiation, Dosimetry, Canada
|
| | | Canada, NRC (National Research Council) | | Complete CMCs in Ionizing Radiation for Canada (.pdf file) |  | | Absorbed dose rate to water. Ionization chambers, 6.7E-03 Gy s-1 to 1.6E-02 Gy s-1 | | Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 1 | | Irradiation in a calibrated field at 5 cm depth in water phantom | | Co-60: 10 cm by 10 cm field at 1 m distance, 5 cm depth | | Reference standard: Water calorimeter | | Source of traceability: NRC | | Approved on 04 November 2004 | | Internal NMI service identifier: SIM-RAD-NRC-1013 |
| | | Absorbed dose rate to water. Ionization chambers, 1.7E-03 Gy s-1 to 2.0E-01 Gy s-1 | | Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 1 | | Irradiation in a calibrated field at 5 cm or 10 cm depth in water phantom | | Photons, high energy: 6 MV to 25 MV, 10 cm by 10 cm field at 1 m distance | | Reference standard: Water calorimeter | | Source of traceability: NRC | | Approved on 04 November 2004 | | Internal NMI service identifier: SIM-RAD-NRC-1014 |
| | | Air kerma. Personal dosimeters, 1.0E-04 Gy to 1.0E-01 Gy | | Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 2 | | Irradiation in a calibrated field in air or on PMMA phantom | | Co-60: colliminated beam from a shuttered, shielded head | | Reference standard: Secondary standard ionization chamber | | Source of traceability: NRC | | Approved on 04 November 2004 | | Internal NMI service identifier: SIM-RAD-NRC-1009 |
| | | Air kerma. Personal dosimeters, 1.0E-04 Gy to 1.0E-01 Gy | | Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 2 | | Irradiation in a calibrated field in air or on PMMA phantom | | X-ray, 10 kV to 50 kV: HVL matched to client requirements | | Reference standard: Free-air chambers | | Source of traceability: NRC | | Approved on 04 November 2004 | | Internal NMI service identifier: SIM-RAD-NRC-1002 |
| | | Air kerma. Personal dosimeters, 1.0E-04 Gy to 1.0E-01 Gy | | Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 2 | | Irradiation in a calibrated field in air or on PMMA phantom | | X-ray, 50 kV to 300 kV: HVL matched to client requirements | | Reference standard: Free-air chambers | | Source of traceability: NRC | | Approved on 04 November 2004 | | Internal NMI service identifier: SIM-RAD-NRC-1004 |
| | | Air kerma rate. Ionization chambers (other dose/rate instruments in special tests), 1.0E-04 Gy s-1 to 2.0E-02 Gy s-1 | | Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 1 | | Irradiation in a calibrated field in air | | Co-60: colliminated beam from a shuttered, shielded head | | Reference standard: Graphite cavity chamber | | Source of traceability: NRC | | Approved on 04 November 2004 | | Internal NMI service identifier: SIM-RAD-NRC-1006 |
|