Calibration and Measurement Capabilities
Ionizing Radiation
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a2 + b2]1/2
 
Result of the search
Your selection : Ionizing Radiation, Dosimetry, Canada
 
Canada, NRC (National Research Council)
Complete CMCs in Ionizing Radiation for Canada (.pdf file)
Absorbed dose rate to water. Ionization chambers, 6.7E-03 Gy s-1 to 1.6E-02 Gy s-1
Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 1
Irradiation in a calibrated field at 5 cm depth in water phantom
Co-60: 10 cm by 10 cm field at 1 m distance, 5 cm depth
Reference standard: Water calorimeter
Source of traceability: NRC
Approved on 04 November 2004
Internal NMI service identifier: SIM-RAD-NRC-1013
 
Absorbed dose rate to water. Ionization chambers, 1.7E-03 Gy s-1 to 2.0E-01 Gy s-1
Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 1
Irradiation in a calibrated field at 5 cm or 10 cm depth in water phantom
Photons, high energy: 6 MV to 25 MV, 10 cm by 10 cm field at 1 m distance
Reference standard: Water calorimeter
Source of traceability: NRC
Approved on 04 November 2004
Internal NMI service identifier: SIM-RAD-NRC-1014
 
Air kerma. Personal dosimeters, 1.0E-04 Gy to 1.0E-01 Gy
Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 2
Irradiation in a calibrated field in air or on PMMA phantom
Co-60: colliminated beam from a shuttered, shielded head
Reference standard: Secondary standard ionization chamber
Source of traceability: NRC
Approved on 04 November 2004
Internal NMI service identifier: SIM-RAD-NRC-1009
 
Air kerma. Personal dosimeters, 1.0E-04 Gy to 1.0E-01 Gy
Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 2
Irradiation in a calibrated field in air or on PMMA phantom
X-ray, 10 kV to 50 kV: HVL matched to client requirements
Reference standard: Free-air chambers
Source of traceability: NRC
Approved on 04 November 2004
Internal NMI service identifier: SIM-RAD-NRC-1002
 
Air kerma. Personal dosimeters, 1.0E-04 Gy to 1.0E-01 Gy
Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 2
Irradiation in a calibrated field in air or on PMMA phantom
X-ray, 50 kV to 300 kV: HVL matched to client requirements
Reference standard: Free-air chambers
Source of traceability: NRC
Approved on 04 November 2004
Internal NMI service identifier: SIM-RAD-NRC-1004
 
Air kerma rate. Ionization chambers (other dose/rate instruments in special tests), 1.0E-04 Gy s-1 to 2.0E-02 Gy s-1
Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 1
Irradiation in a calibrated field in air
Co-60: colliminated beam from a shuttered, shielded head
Reference standard: Graphite cavity chamber
Source of traceability: NRC
Approved on 04 November 2004
Internal NMI service identifier: SIM-RAD-NRC-1006


 
 1  2