Calibration and Measurement Capabilities
Electricity and Magnetism
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a2 + b2]1/2
 
Result of the search
Your selection : Electricity and Magnetism
 
Georgia, GEOSTM (Georgian National Agency for Standards and Metrology)
Complete CMCs in Electricity and Magnetism for Georgia (.PDF file)
DC resistance standards and sources, high values. Resistance standards, resistance boxes,
> 1.00E+06  to 2.00E+09 
Absolute expanded uncertainty (k = 2, level of confidence 95%) in : 20E-06R to 1.6E-03R, with resistance R
Direct measurement with a DMM
Temperature: (23 ± 3) °C
Approved on 19 May 2015
Internal NMI service identifier: GEOSTM/EM-21 to EM-24
Uncertainty table
 
DC resistance standards and sources, intermediate values. Resistance standards, 10 k
Absolute expanded uncertainty (k = 2, level of confidence 95%) in : 5E-06R, with resistance R
Substitution with a DMM
Temperature: (23 ± 3) °C
Approved on 19 May 2015
Internal NMI service identifier: GEOSTM/EM-14
 
DC resistance standards and sources, intermediate values. Resistance standards, resistance boxes, > 1  to 1.00E+06 
Absolute expanded uncertainty (k = 2, level of confidence 95%) in : (15E-06R + 10E-06) to 20E-06R, with resistance R
Direct measurement with a DMM
Temperature: (23 ± 3) °C
Approved on 19 May 2015
Internal NMI service identifier: GEOSTM/EM-14 to EM-21
Uncertainty table
 
DC resistance standards and sources, low values. Resistance standards,
Absolute expanded uncertainty (k = 2, level of confidence 95%) in : 20E-06R, with resistance R
Substitution with a DMM
Temperature: (23 ± 3) °C
Approved on 19 May 2015
Internal NMI service identifier: GEOSTM/EM-13
 
DC resistance standards and sources, low values. Resistance standards, resistance boxes,
> 0.01  to 1 
Absolute expanded uncertainty (k = 2, level of confidence 95%) in : (15E-06R + 10E-06) to 20E-06R, with resistance R
Direct measurement with a DMM
Temperature: (23 ± 3) °C
Approved on 19 May 2015
Internal NMI service identifier: GEOSTM/EM-13 and EM-15
Uncertainty table
 
DC voltage meters, intermediate values. DC voltage calibrator, > 0.001 V to 1100 V
Absolute expanded uncertainty (k = 2, level of confidence 95%) in V: (2E-06U + 3E-06) to (6E-06U + 600E-06), with voltage U
Direct measurement
Temperature: (23 ± 3) °C
Approved on 19 May 2015
Internal NMI service identifier: GEOSTM/EM-8 to EM-12
Uncertainty table


 