Calibration and Measurement Capabilities
Electricity and Magnetism
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a2 + b2]1/2
 
Result of the search
Your selection : Electricity and Magnetism
 
Panama, CENAMEP AIP (Centro Nacional de Metrología de Panamá AIP)
Complete CMCs in Electricity and Magnetism for Panama (.PDF file)
AC current up to 100 A: meters. Multimeter, 0.1 A to 2 A
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 200 to 325
Direct comparison
Frequency: 60 Hz to 5 kHz
Approved on 04 April 2017
Internal NMI service identifier: CENAMEP AIP/CMP-E4-S001
Uncertainty table
 
AC power and energy: single phase (frequency above or equal to 400 Hz), active energy. Energy meter, 0.5 Wh to 400 Wh
Relative expanded uncertainty (k = 2, level of confidence 95%) in µWh/VAh: 95
Direct comparison
Voltage: 120 V to 240 V
Current: 0.5 A to 100 A
Frequency: 50 Hz to 60 Hz
Power Factor: 1, 0.5 inductive, 0.5 capacitive
Measuring time: 60 s
Approved on 04 April 2017
Internal NMI service identifier: CMP-E2-S001,-S002,-S003; CMP-E0-S012, -S013
 
AC power and energy: three phase, active energy. Energy meter, 1.5 Wh to 1200 Wh
Relative expanded uncertainty (k = 2, level of confidence 95%) in µWh/VAh: 100
Direct comparison
Voltage: 120 V to 240 V
Current: 0.5 A to 100 A
Frequency: 50 Hz to 60 Hz
Power Factor: 1, 0.5 inductive, 0.5 capacitive
Measuring time: 60 s
Approved on 04 April 2017
Internal NMI service identifier: CMP-E2-S001,-S002,-S003; CMP-E0-S012, -S013
 
AC voltage up to 1100 V: meters. Multimeter, 0.1 V to 700 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 70 to 185
Direct comparison
Frequency: 60 Hz to 10 kHz
Approved on 04 April 2017
Internal NMI service identifier: CENAMEP AIP/CMP-E4-S001
Uncertainty table
 
DC current meters: intermediate values. Multimeter, 1E-04 A to 2 A
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 55 to 120
Direct comparison
Approved on 04 April 2017
Internal NMI service identifier: CENAMEP AIP/CMP-E4-S001
Uncertainty table
 
DC resistance meters: intermediate values. Multimeter, to 1E+08 
Relative expanded uncertainty (k = 2, level of confidence 95%) in µ/: 15 to 210
Direct comparison
Resistance: (1, 10, 19, 100, 190) , (1, 1.9, 10, 19, 100, 190) k, (1, 1.9, 10, 19, 100) M
Approved on 04 April 2017
Internal NMI service identifier: CENAMEP AIP/CMP-E4-S001
Uncertainty table


 
 1  2