Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
CMCs - Result of the search
Physics
Acoustics, Ultrasound, Vibration
Electricity and Magnetism
Length
Mass and related quantities
Photometry and Radiometry
Ionizing Radiation
Thermometry
Time and Frequency
Chemistry
Chemistry
Traceability to the SI through the BIPM
BIPM calibration and measurement services
Related links
KCDB Statistics
KCDB FAQs
KCDB Reports
CIPM MRA
JCRB
Find my NMI
Metrologia
Contact us
BIPM.KCDB@bipm.org
Calibration and Measurement Capabilities
Electricity and Magnetism
In the CMCs uncertainty statements, the notation Q[a, b] stands for the root-sum-square of the terms between brackets: Q[a, b] = [a2 + b2]1/2
 
Result of the search
Your selection : Electricity and Magnetism
 
Canada, NRC (National Research Council)
Complete CMCs in Electricity and Magnetism for Canada (.PDF file)
AC-DC current transfer. Thermal converter plus shunt, AC-DC transfer standard plus shunt, 0.01 A to 100 A
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 7 to 36
Direct comparison
Frequency: 10 Hz to 100 kHz
Approved on 04 April 2017
Internal NMI service identifier: NRC/A33-02-07-01
Uncertainty table
 
AC-DC voltage transfer. Multijunction thermal voltage converter, 0.8 V to 2 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 1
Direct comparison
Frequency: 40 Hz to 5 kHz
Approved on 04 April 2017
Internal NMI service identifier: NRC/A33-02-07-01
 
AC-DC voltage transfer. Thermal transfer standard based on multijunctions or solid state sensor, 80 V to 220 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 2.3
Direct comparison
Frequency: 50 Hz to 400 Hz
Approved on 04 April 2017
Internal NMI service identifier: NRC/A33-02-07-01
 
AC current ratio (in-phase and quadrature). Current transformer, 0.005  to 4.80E+05 
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 5 to 10
In-house and on-site
Frequency: 50 Hz, 60 Hz, 400 Hz
Alternating current: 60 kA
Approved on 04 April 2017
Internal NMI service identifier: NRC/A33-10-1-1
Uncertainty table
 
AC resistance (magnitude). AC resistors and shunts, 1.00E-05  to 1.00E+06 
Relative expanded uncertainty (k = 2, level of confidence 95%) in µ/: 10
Ratio measurement against standard
Frequency: 50 Hz, 60 Hz
Current: to 10 kA
Approved on 04 April 2017
Internal NMI service identifier: NRC/A33-10-5-1
 
AC resistance (phase). AC resistors and shunts, -0.1 rad to 0.1 rad
Absolute expanded uncertainty (k = 2, level of confidence 95%) in µrad: 10
Ratio measurement against standard
Frequency: 50 Hz, 60 Hz
Current: to 10 kA
Approved on 04 April 2017
Internal NMI service identifier: NRC/A33-10-5-1


 