07 February 2012
  Supplementary comparison COOMET.L-S7
Publication of the Final Report of supplementary comparison COOMET.L-S7 on standards of Length of nominal values 100 mm.
06 February 2012
  Key comparison APMP.AUV.A-K3
Publication of APMP.AUV.A-K3 results linked to those of CCAUV.A-K3. These are key comparisons of pressure sensitivity level of LS2P laboratory standard microphones.
27 January 2012
  Key comparison CCQM-K74
Publication of the Final Report and of the results of CCQM-K74, a key comparison on Nitrogen dioxide in Nitrogen at a nominal mole fraction of 10 µmol/mol.
25 January 2012
  Key comparison CCQM-K77
Publication of the Final Report and of the results of CCQM-K77, a key comparison of synthetic standards of refinery gas.
17 January 2012
  Supplementary comparison SIM.QM-S2
Publication of the Final Report of supplementary comparison SIM.QM-S2 on trace elements in water.
13 January 2012
  Key comparison BIPM.EM-K13.b
Update of BIPM.EM-K13.b results with data from NSAI NML of 2010, and KRISS of 2011. This is a BIPM key comparison of resistance of nominal value 10 kiloohms.
11 January 2012
  Key comparison CCQM-K86
Publication of CCQM-K86 results. This is a key comparison of relative quantification of genomic DNA fragments extracted from a biological tissue.
10 January 2012
  Key comparison APMP.L-K11.1
Publication of APMP.L-K11.1 results, joined to those of BIPM.L-K11.
09 January 2012
  Key comparison BIPM.EM-K13.a
Update of BIPM.EM-K13.a results with data from NSAI NML of 2010. This is a BIPM key comparison of resistance of nominal value 1 ohm.
09 January 2012
  Key comparison CCQM-K66
Publication of CCQM-K66 results, a comparison of purity of Methane.
06 January 2012
  Key comparison BIPM.RI(II)-K4.Tc-99m

Update of BIPM.RI(II)-K4.Tc-99m results with data from KRISS, linked to those of BIPM.RI(II)-K1.Tc-99m. These are BIPM key comparisons of activity of radionuclide Tc-99m. Measurements are carried out at the BIPM for K1 and on site for K4, using the SIR Transfer Instrument (SIRTI).

04 January 2012
  Key comparison BIPM.EM-K10.b
Update of BIPM.EM-K10.b results with data from CMI dated 2011. This is a BIPM key comparison of Josephson DC voltage at 10 V.